Refractive Outcomes and Ocular Biometry of Two Swept-Source Optical Coherence Tomography-Based Biometers With Segmental or Equivalent Refractive Indices (ORION)

Last updated: April 24, 2024
Sponsor: Walailak University
Overall Status: Active - Recruiting

Phase

N/A

Condition

Eye Disorders/infections

Eye Disease

Vision Loss

Treatment

Argos (Alcon Laboratories, Inc.)

IOLMaster 700 (Carl Zeiss Meditec AG)

Clinical Study ID

NCT06377007
WU66290
WU66290
  • Ages 50-85
  • All Genders
  • Accepts Healthy Volunteers

Study Summary

Cataract surgery represents a common surgical intervention, encompassing the extraction of the opaque natural crystalline lens, followed by the substitution with an artificial intraocular lens (IOL). To ascertain an IOL possessing optimal power, antecedent to the surgery, preoperative evaluations are conducted through the utilization of a biometric devices. Diverse categories of these instruments are accessible, each harnessing distinct optical methodologies or mathematical algorithms to ascertain the most fitting IOL power. The principal objective of this study was to evaluate the ocular biometry and the predictive precision outcome of a biometer that uses standard keratometry to the prediction accuracy of another biometer that uses Total Keratometry.

Eligibility Criteria

Inclusion

Inclusion Criteria:

• Patients with cataract and/or presbyopia who will undergo intraocular lens implantation.

Exclusion

Exclusion Criteria:

  • Central corneal thickness less than 490 mm or greater than 600 mm
  • Contact lens use within 2 months of cataract surgery
  • Severe dry eye
  • Corneal or retinal disease affecting visual outcome
  • Corneal astigmatism greater than 1.00 D
  • Prior corneal refractive surgery
  • Dense cataract that does not allow measurements to be taken with an optical biometricssystem.

Study Design

Total Participants: 142
Treatment Group(s): 2
Primary Treatment: Argos (Alcon Laboratories, Inc.)
Phase:
Study Start date:
January 01, 2024
Estimated Completion Date:
December 30, 2025

Study Description

Two swept-source optical coherence tomography (SS-OCT) biometers, namely the Argos and the IOLMaster 700, will be employed for the preoperative assessment of the eyes of all subjects who will undergo cataract surgery at the Eye Outpatient Department (OPD) of Walailak University Hospital. The sequence of biometry measurements will be randomized among the subjects. In Group 1, measurements will be initially conducted using the Argos device, followed by the IOLMaster 700 device. Conversely, Group 2 subjects will undergo measurements with the IOLMaster 700 device first, followed by the Argos device. The sequence will be continuous without any breaks. The analysis will encompass the right eyes of each subject.

For the purpose of preoperative planning, the Argos device will utilize the Barrett Universal Formula II "K," whereas the IOLMaster 700 device will employ the Barrett Universal II TK formula. The objective for all eyes will be to achieve a plano outcome. In instances where the suggested intraocular lens (IOL) power differs between the two biometers, the IOL power recommended by the IOLMaster 700 device will be selected. Cataract surgeries will be exclusively performed by a seasoned surgeon (SM), who will adhere to a consistent approach involving a clear temporal incision (2.75 mm) followed by manual capsulorhexis. Refractive and visual outcomes will be evaluated within a postoperative timeframe of 28 to 42 days. Subjective refractions will be conducted by an optometrist, ensuring blinding to the biometry data.

The primary endpoint of this study will be the mean absolute prediction error exhibited by each SS-OCT biometer. The computation of the absolute prediction error will involve determining the absolute disparity between the predicted spherical equivalent refraction derived from preoperative planning and the actual measured spherical equivalent refraction (manifest). Secondary objectives will encompass the median absolute prediction error and the proportion of eyes with an absolute prediction error equal to or less than 0.25 D and 0.5 D.