Study design Thirty patients will be treated using the principles of guided bone
regeneration utilizing a full thickness flap for ridge preservation. Fifteen test
patients will receive an intrasocket demineralized and mineralized combination putty
allograft with a regenerative tissue matrix membrane. The positive control group of
fifteen patients will receive an intrasocket synthetic resorbable calcium phosphosilicate
putty alloplast graft covered with a regenerative tissue matrix membrane. Approximately,
four months post-surgery, a trephine core will be taken from the grafted site immediately
prior to implant placement and submitted for histologic processing.
Presurgical Management
Each patient will receive a diagnostic work-up including standardized radiographs
(periapical), cone beam computed tomography (CBCT) scan, study casts, clinical
photographs, and a clinical examination to record attachment level, probing depth,
recession, and mobility of teeth adjacent to the extracted sites. Customized acrylic
occlusal stents will be fabricated on the study casts to serve as fixed reference guides
for the measurements. Presurgical preparation will include detailed oral hygiene
instructions. Baseline data will be collected just before the surgical phase of the
treatment. Baseline data will include:
Clinical Measurements
Baseline and 4-month data will include the following:
For the extraction site or adjacent teeth when necessary:
Plaque index
Gingival index
Gingival margin levels: Measured from cemento-enamel junction (CEJ) to the gingival
margin.
Keratinized tissue: Measured from the gingival margin to the mucogingival junction.
Clinical attachment level: Measured from CEJ to the bottom of the clinical
periodontal pocket.
Clinical tooth mobility: Measured by using the modified Miller's Index.
Ridge dimensions: Post-extraction and 4 month healing stent and caliper
measurements.
Soft tissue thickness.
Radiographic examination including CBCT
Clinical photographs.
Histologic Measurements
For preservation sites:
- Trephine core specimens will be evaluated to determine percent vital bone, non-vital
bone, and trabecular space. Step serial sections will be taken from each longitudinally
sectioned core. The sections will be stained with hematoxylin and eosin. Ten slides per
patients will be prepared with at least 4 sections per slide. For each patient, 6 of 10
slides will be assessed. The mean percentage of vital and nonvital bone, and trabecular
space will be determined for each patient by using an American Optical microscope at 150X
with 10 X 10 ocular grid.
Potential Risks
There are known physical risks linked with tooth extraction with the placement of the
bone graft materials (human) in the jaw as well as risks linked with surgical implant
placement. The potential risks are the same as the risks of any minor surgery in the
mouth. These risks include:
Infection of treated area (usually mild, rare less than 1%)
Mild bruising and/or bleeding (less likely 1-39%)
Mild swelling (more than 40%)
Transient but occasional paresthesia or numbness of lips, tongue, chin or gum
(usually mild, rare less than 1%)
Loss of the bone graft (mild to moderate, rare less than 1%)
There may also be additional risks that are currently unforeseeable.
Adverse Events Definitions An "adverse event" refers to any adverse experience occurring
during the clinical study period, whether associated or not associated with the study
test articles or procedures. A "serious adverse event" means any experiences that suggest
significant hazard, contraindication, side effect, or precaution. With respect to human
clinical experience, a serious adverse event includes any experience that is fatal or
life threatening, causes a persistent or permanent disability, requires initial or
prolonged hospitalization, requires medical or surgical intervention to prevent permanent
impairment or damage, or is a congenital anomaly.
An "unanticipated adverse event" is one that is not identified in nature, severity, or
frequency.
Procedure Adverse events will be collected by observing and interviewing the subject
during the study. Subjects who experience any significant problems during the study are
to call and discuss them with investigator. Any suspected adverse event or allergic
response is to be thoroughly examined by investigator. All adverse events are to be
reported. All subjects experiencing adverse events will be followed by the investigator
until there is a return to the subject's baseline condition or a clinically satisfactory
resolution is achieved. Adverse events that are serious or unanticipated are to be
reported immediately by phone to the study director and promptly reported to the
institutional review board (IRB), which will include the event date, description of the
adverse event, study treatment involved, and outcome of event. Examples of expected, but
rarely occurring adverse events related to grafting treatment include clinical
observation of infection, flap necrosis, severe inflammation, and severe pain.
Measurement techniques All probing measurements will be taken using the University of
North Carolina probe. A masked, calibrated examiner will perform the initial examination
and the measurements at the time of initial surgery using a customized stent. The mentor
will check these measurements. Differences of more than 1.0 mm between examiners will be
remeasured by the blinded examiner. Measurements will again be repeated at the 4-month
examination using the same techniques.
Statistical Analysis Means and standard deviations will be calculated for all parameters.
A paired t-test will be used to evaluate the statistical significance of the differences
between initial and final data. An unpaired t-test will be used to evaluate statistical
differences between the test and control groups. The sample size of 15 per group gives
83% statistical power to detect a difference of 1 mm between groups. Power calculations
were based on data from previous studies.
Research materials, records and privacy: The de-identified data collected will be entered
in an excel spreadsheet, which will be password protected. The data will be stored in an
encrypted computer, which is also password protected. No one will have access to this
data other than the individual collecting it and the PI. No personal identifying
information will be collected or needed for the study analytical purposes.
Significance The results of this study will allow comparison of a combination putty
allograft versus demineralized putty allograft covered by a regenerative tissue matrix
membrane for ridge preservation in terms of the effect on vertical and horizontal
dimensions, suitability of the site to receive an implant, and histologic bone quality.
The Plaque Index
The modified O'Leary plaque index (plaque free sites) will be used to obtain dichotomous
plaque scores at 6 sites per tooth.
The Gingival Index
The Gingival Index (Lobene et al. 1986) will be measured. Scores will be as follows:
0- Absence of inflammation
Mild inflammation; slight change in color, little change in texture of any portion
of but not the entire marginal or papillary gingival unit.
Mild inflammation; criteria as above but involving the entire marginal or papillary
gingival unit.
Moderate inflammation; glazing, redness, edema, and/or hypertrophy of the marginal
or papillary gingival unit.
Severe inflammation; marked redness, edema and/or hypertrophy of the marginal or
papillary gingival unit, spontaneous bleeding, congestion, or ulceration.
Each gingival unit (buccal, lingual, mesiobuccal, distobuccal, mesiolingual, and
distolingual) of the individual tooth will be given a score from 0-4, called the gingival
index for the area. The scores from the 6 areas of the tooth are added and divided by 6
to give the gingival index for the tooth.
Standardized Radiographic technique
An occlusal stent is used to provide a stable foundation for the radiograph holder. The
stent is placed on a cast and the Rinn radiograph holder is positioned to allow as near
as possible paralleling technique. Radiographs will be taken at baseline and again at 4
months.
Arithmetic determinations:
Change in horizontal ridge dimension: Pre-op width - post-op width
Change in vertical ridge dimension: Pre-op stent distance - Post-op stent distance
Tooth mobility
Miller proposed the following tooth mobility index:
0 - Mobility of the crown is within normal physiologic limits.
- Mobility of the crown up to 0.5 mm in one direction. Does not exceed 1.0 mm in
both directions.
- Mobility of the crown from 0.5 to 1 mm in one direction. Does not exceed 2.0 mm in
both directions.
- Mobility of the crown exceeding 1 mm in one direction and/or vertical
depressibility. Greater than 2.0 mm in both directions and/or vertical
depressibility.
The index that will be used in the study is a modification of Miller's index (Laster et
al., 1975) where half scores are used. Thus, scores of 0, 0.5, 1, 1.5, 2, 2.5, and 3 will
be utilized.
Stent fabrication
Rigid stents will be made of 3 mm thick acrylic plates in order to obtain reproducible
measurements. The acrylic will be pressed over a model cast and cured using a curing
light so that the edge extends just apical to the prominence of the teeth. Holes will be
cut into the splint with a high-speed handpiece in order to allow probing in the needed
areas of edentulous ridge in order to produce reproducible probing spots and directions
of probe insertions. The holes will be made on the buccal and lingual aspects of the
splint for horizontal readings and on the top aspect for vertical readings.
Examiner calibration: Probing and caliper measurements.
The data will be compared from indices or measurements taken by the examiner on three
different patients at two different times within a 60-minute period to measure the
intra-examiner accuracy and reproducibility.
A minimum of three subjects are to be recruited to participate in the calibration.
The subjects should exhibit a range of the criteria being assessed in the index or
measurements being performed (i.e., subjects with moderate to severe periodontal
disease).
The examiner will score 3 teeth per subject within the same quadrant.
The examiner will measure each subject, calling out the measurements, site by site,
while the assistant records.
Duplicate measurements of the subjects will be taken within 60 minutes following the
initial measurements. The assistant will record the second set of data.
The examiner will not compare the two sets of data at any time during the
calibration. The examiner will not discuss their measurements with the assistant or
the subject during the calibration.
The assistant recording the data will be responsible for handling the data sheets.
The examiner will have no access to any of the data sheets during the course of the
calibration.
The data sets will be analyzed for percent agreement. Acceptable percent agreement
will reflect the limits set for the different parameters measured.
Acceptable percent agreement will be: 90% within ±1mm for probing depth, recession and
attachment level and 70% within 0 mm.