IOL-capsular Complex After Different Intraocular Lenses Implantation in Patients With High Myopia

Last updated: February 21, 2022
Sponsor: Wenzhou Medical University
Overall Status: Active - Recruiting

Phase

N/A

Condition

Eye Disease

Myopia

Eye Disorders/infections

Treatment

N/A

Clinical Study ID

NCT05255796
20211213CTR
  • Ages 18-90
  • All Genders

Study Summary

The IOL-capsular complex is formed after cataract surgery and intraocular lens (IOL) implantation. Early postoperative mechanical wrapping of the anterior and posterior capsules plays a significant role in preventing IOL decentration and tilt, as well as formation of the IOL-capsular complex which reduces the incidence of posterior cataract opacity. IOL decentration ≥ 0.4 mm or/and IOL tilt ≥7degree were considered clinically significant cause of poor post-surgery visual quality especially for optical sophisticated IOLs. This negative impact does not affect various types of IOLs equally. Several studies indicated that AL was an independent risk factor of IOL decentration and tilt for emmetropic or moderate myopic eyes. For patients with high myopia, they often have a longer axial length and a larger capsule diameter, which reduces the rotational stability of the IOL and may lead to tilt, decentration and displacement of IOL. Currently, there is no literature guidance to compare the results of cataract surgery combined various types of IOLs implantation in patients with high myopia. The novel anterior segment optical coherence tomography (AS-OCT) device, CASIA2 can evaluate the IOL capsule bending and the lens position after cataract surgery. Also, CASIA2 can be used to documented the dynamic changes of IOL-capsular complex after surgery.

Eligibility Criteria

Inclusion

Inclusion Criteria:

  • The patients are diagnosed age related cataract or complicated cataract with axiallength over 26mm
  • The patients' age over 18 years old
  • The patients plan to receive cataract surgery in Eye hospital of Wenzhou MedicalUniversity
  • The dialated pupils are over 6mm
  • Patients are willing and able to complete the follow-ups

Exclusion

Exclusion Criteria:

  • Patients with other types of cataract
  • Patients have complications in the surgery and after surgery
  • Patients have other severe diseases of eyes

Study Design

Total Participants: 40
Study Start date:
January 07, 2022
Estimated Completion Date:
December 31, 2022

Study Description

The IOL-capsular complex is formed after cataract surgery and intraocular lens (IOL) implantation. Early postoperative mechanical wrapping of the anterior and posterior capsules plays a significant role in preventing IOL decentration and tilt, as well as formation of the IOL-capsular complex which reduces the incidence of posterior cataract opacity. Although up to 2-3 degree tilt and a 0.2-0.3 mm decentration are common and clinically unnoticed for any design of IOL, larger extent of tilt and decentration has a negative impact on the optical performance. IOL decentration ≥ 0.4 mm or/and IOL tilt ≥7degree were considered clinically significant cause of poor post-surgery visual quality especially for optical sophisticated IOLs. This negative impact does not affect various types of IOLs equally. Several studies indicated that AL was an independent risk factor of IOL decentration and tilt for emmetropic or moderate myopic eyes. However, there is scarce evidence on characteristics and factors associated with clinically significant IOL decentration and tilt in highly myopic eyes. For patients with high myopia, they often have a longer axial length and a larger capsule diameter, which reduces the rotational stability of the IOL and may lead to tilt, decentration and displacement of IOL. Currently, there is no literature guidance to compare the results of cataract surgery combined various types of IOLs implantation in patients with high myopia. The novel anterior segment optical coherence tomography (AS-OCT) device, CASIA2 can evaluate the IOL capsule bending and the lens position after cataract surgery. Also, CASIA2 can be used to documented the dynamic changes of IOL-capsular complex after surgery.

Connect with a study center

  • Eye Hospital of Wenzhou Medical College

    Hangzhou, Zhejiang 325027
    China

    Active - Recruiting

Map preview placeholder

Not the study for you?

Let us help you find the best match. Sign up as a volunteer and receive email notifications when clinical trials are posted in the medical category of interest to you.