Safety and Efficacy of Adaptive Deep Brain Stimulation

Last updated: July 8, 2024
Sponsor: Newronika
Overall Status: Active - Recruiting

Phase

N/A

Condition

N/A

Treatment

AlphaDBS System

Clinical Study ID

NCT04681534
NWK_AlphaDBS_FIM_2019
  • All Genders

Study Summary

The aim of this study is to assess the safety and the potential efficacy of personalized Local Field Potential (LFP)-based adaptive Deep Brain Stimulation (aDBS), using the implantable pulse generator (IPG) of the "AlphaDBS" System, in Parkinson's Disease patients, chronically implanted in subthalamic nucleus (STN) for DBS.

Eligibility Criteria

Inclusion

IPG Replacement Patients:

Inclusion Criteria

  1. Diagnosis of idiopathic PD;

  2. Subject is bilaterally treated with DBS in the STN using a Medtronic Activa PC or Activa RC IPG (mono-channnel or dual channel);

  3. DBS implant for at least 3 years and in need of battery replacement within 12 months after consent;

  4. Patients must be able to understand and sign the informed consent document.

Exclusion criteria

  1. Patients with severe cognitive decline, as resulting from MoCA assessment (MoCA score < 10);

  2. Patients with major psychiatric issues or any other condition that, based on the physician opinion, could interfere with the study conduct (e.g. severe depression, psychosis, etc.);

  3. Patients with any medical conditions potentially interfering with DBS battery replacement surgery (e.g. severe hypertension, active cancer, intake of drugs interfering with the coagulation etc.);

  4. Need to replace or reposition the leads during the IPG replacement procedure;

  5. Patients with > 10 recurrent falls experienced in the 3 months prior to consent;

  6. Patients that cannot tolerate an interruption of DBS stimulation for at least 30 min;

  7. Patients taking less than one levodopa dose per day;

  8. Patients without suitable LFPs recordings or with significant artifacts;

  9. Pregnant or breastfeeding women.

De Novo DBS Patients:

Inclusion Criteria

  1. Patient is ≥ 18 years old;

  2. Patient has been diagnosed with levodopa-responsive idiopathic Parkinson's disease for ≥ 5 years;

  3. The disease stage is II, III or IV according to the Hoehn and Yahr scale

  4. Patient has history of improvement of PD-related symptoms as a direct result of levodopa intake;

  5. Patient has been selected for bilateral STN or GPi DBS, independently from this study, in accordance with local standard of care DBS screening;

  6. Patient has been selected to receive Medtronic leads model 3389 or 37086 or Abbott directional leads model number 6170 or 6172 or 6371, independently from this study, in accordance with local standard of care for DBS;

  7. Patient has DBS-leads circuit integrity assessed and confirmed by impedance testing, before IPG implantation;

  8. MoCA score > 26 in best medical condition;

  9. BDI-II score < 17 in best medical condition;

  10. UPDRS-III improvement by ≥ 33% with levodopa challenge test (at approximately 90 min from the intake of the usual morning levodopa dose plus 30%);

  11. Patient is able to understand the study requirements and the treatment procedures and has provided written informed consent to participate;

  12. Patient has a responsible caregiver who will help completing the 3-day diary, provide feedback on activities of daily living (ADL), and ensure the patient complies with visit schedule;

  13. Patient is on stable PD-medication for one month prior surgery;

  14. Patient is willing and able to attend all study-required visits, complete the study procedures and attend appropriate follow up visits.

Exclusion Criteria

  1. Patient has contraindications for DBS surgery, including any intracranial abnormality (e.g., generalized atrophy, vascular malformation, hydrocephalus, hematoma, cavernous or venous angioma, tumor or metastases, midline shift, etc.) or metallic implant (e.g., aneurysm clip, cochlear implant, etc.);

  2. Patient has a history of suicide attempt or current active suicidal ideation as determined by a positive response to Item 2-5 of suicide ideation sub-scale of the Columbia Suicide Severity Rating Scale (C-SSRS);

  3. Patient has dementia, major depression, seizures, congestive heart failure, uncontrolled diabetes, dialysis, substance use disorders as described in DSM-V, or any other severe medical condition;

  4. Patient has any medical condition that could interfere with study procedures, confound the assessment of study endpoints, or prevent a proper data collection;

  5. Patient had confirmation of diagnosis of a terminal illness associated with survival < 12 months;

  6. Patient needs repeated MRI scans;

  7. Patient requires diathermy, transcranial magnetic stimulation (TMS), or electroconvulsive therapy (ECT);

  8. Patient carries an electrical or electromagnetic implant (e.g., cochlear prosthesis, pacemaker, neurostimulator, etc.);

  9. Patient has, or plans to obtain, an implanted electrical stimulation medical device and/or an implanted medication pump (e.g., DUOPATM infusion pump) and/or is treated with a portable infusion pump;

  10. Patient is on anticoagulant therapy which cannot be paused for > 5 days before IPG implant surgery;

  11. Patient with a history of cranial surgery including ablation procedure or any other previous neurosurgical procedure for the treatment of PD symptoms on either side of the brain;

  12. Patient is currently participating in another clinical study (excluding any sub-study of the present study);

  13. Patient is a female who is breastfeeding or of child-bearing potential with a positive urine pregnancy test or not using adequate contraception;

  14. Patients without suitable LFPs recordings or with significant artifacts.

Study Design

Total Participants: 15
Treatment Group(s): 1
Primary Treatment: AlphaDBS System
Phase:
Study Start date:
January 26, 2021
Estimated Completion Date:
December 30, 2025

Study Description

The study protocol is organized in two phases: the "short-term follow-up" and the "long-term follow-up".

PD patients in need of IPG replacement or "de novo DBS" patients will be screened for enrollment eligibility.

For the "short-term follow-up", randomized patients will undergo 2 days of experimental sessions (i.e. one per each type of stimulation mode, cDBS and aDBS), in a well-controlled environment (i.e. during hospitalization). This part of the study will collect information on safety and potential efficacy endpoints as assessed by experienced neurologists. The "short term follow-up" phase will be considered complete when the endpoint assessment has been performed for all patients.

Patients, who will not experience severe side effects and who will be deemed suitable by the neurologist, will be eligible to continue in the "long-term follow-up" phase (i.e. 1 month) in their "home" environment. The "AlphaDBS" System will deliver the stimulation in aDBS or cDBS mode, for two weeks in each mode.

Connect with a study center

  • Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico

    Milan,
    Italy

    Active - Recruiting

  • IRCCS Istituto Neurologico Carlo Besta

    Milan,
    Italy

    Completed

  • Azienda Ospedale Universitario di Padova - Università di Padova

    Padova,
    Italy

    Site Not Available

  • Fondazione Policlinico Universitario Agostino Gemelli IRCCS

    Rome,
    Italy

    Completed

  • AOU Città della Salute e della Scienza di Torino

    Turin,
    Italy

    Completed

  • Maastricht Medical Center

    Maastricht,
    Netherlands

    Site Not Available

  • Copernicus Podmiot Leczniczy

    Gdańsk,
    Poland

    Site Not Available

  • Narodowy Instytut Onkologii im. Marii Skłodowskiej-Curie - Państwowy Instytut Badawczy

    Warsaw,
    Poland

    Completed

Not the study for you?

Let us help you find the best match. Sign up as a volunteer and receive email notifications when clinical trials are posted in the medical category of interest to you.