Radiotherapy plays an important role in non-small cell lung cancer (NSCLC), and concurrent chemoradiation is considered to be the standard treatment for locally advanced NSCLC. However, due to the patient's physical condition, comorbidities and other reasons, only about 1/3 of patients can receive concurrent chemoradiation. Radiotherapy alone or sequential chemoradiation has become the treatment protocol for most patients. Hypofractionated radiotherapy can be used in NSCLC because it can shorten the over treatment time and may potentially reduce the effect of accelerated repopulation and obtain higher biological effective dose(BED).So far, the vast majority of radiotherapy prescriptions have given a uniform dose of 60 Gy. This unified prescription dosage approach is completely inconsistent with the concept of precision treatment. The Netherlands MAASTRO put forward the concept of in silico radiotherapy prescription, that is: the normal tissue limits are uniform, such as: V20% ≤ 30%, spinal cord 0> 45Gy, etc., This radiation prescription could reach the limits of the normal tissue of every patient; if no one tissue limits were reached, the highest dose was set up to 79.2 Gy (1.8 Gy, BID). MAASTRO applied this "iso-toxic" radiotherapy prescription and used accelerated hyperfractionation technology so that each patient received the maximum individualized radiation dose as possible. We will integrate this concept with hypofractionated radiotherapy in order to further improve patient survival.
Radiotherapy plays an important role in non-small cell lung cancer (NSCLC), and concurrent chemoradiation is considered to be the standard treatment for locally advanced NSCLC. However, due to the patient's physical condition, comorbidities and other reasons, only about 1/3 of patients can receive concurrent chemoradiation. Radiotherapy alone or sequential chemoradiation has become the treatment protocol for most patients. Hypofractionated radiotherapy can be used in NSCLC because it can shorten the over treatment time and may potentially reduce the effect of accelerated repopulation and obtain higher biological effective dose(BED) So far, the vast majority of radiotherapy prescriptions have given a uniform dose of radiotherapy to all patients, regardless of individual factors such as tumor size, location, and adjacent vital organs, which may cause two consequences: First, small-volume tumors may, not receive enough radiation dose, resulting in a decrease in local control rates. Second, for large volumes of tumors or tumors adjacent to vital organs, even the "so-called standard dose" (60 Gy) may cause serious damage to normal tissues. This unified prescription dosage approach is completely inconsistent with the concept of precision treatment. The Netherlands MAASTRO put forward the concept of in silico radiotherapy prescription, that is: the normal tissue limits are uniform, such as: V20% ≤ 30%, spinal cord 0> 45Gy, etc., and each patient receives a different dose of radiation therapy. This radiation prescription could reach the limits of the normal tissue of every patient; if no one tissue limits were reached, the highest dose was set up to 79.2 Gy (1.8 Gy, BID). MAASTRO applied this "iso-toxic" radiotherapy prescription and used accelerated hyperfractionation technology so that each patient received the maximum individualized radiation dose as .From the model study to the long-term survival results, a series of encouraging results were achieved. The use of an individualized radiotherapy prescription based on iso-toxicity for the treatment of NSCLC in large-segment radiotherapy is expected to achieve: 1. For patients with small tumor volumes and no adjacent to vital organs, a higher radiation dose is given under safe conditions. 2. For patients with larger volumes of tumors or adjacent to vital organs, give safer doses.
Condition | Carcinoma, Non-Small-Cell Lung |
---|---|
Treatment | isotoxic hypofractionation |
Clinical Study Identifier | NCT03606291 |
Sponsor | The Second Hospital of Hebei Medical University |
Last Modified on | 26 May 2022 |
,
You have contacted , on
Your message has been sent to the study team at ,
You are contacting
Primary Contact
Additional screening procedures may be conducted by the study team before you can be confirmed eligible to participate.
Learn moreIf you are confirmed eligible after full screening, you will be required to understand and sign the informed consent if you decide to enroll in the study. Once enrolled you may be asked to make scheduled visits over a period of time.
Learn moreComplete your scheduled study participation activities and then you are done. You may receive summary of study results if provided by the sponsor.
Learn moreEvery year hundreds of thousands of volunteers step forward to participate in research. Sign up as a volunteer and receive email notifications when clinical trials are posted in the medical category of interest to you.
Sign up as volunteer
Lorem ipsum dolor sit amet consectetur, adipisicing elit. Ipsa vel nobis alias. Quae eveniet velit voluptate quo doloribus maxime et dicta in sequi, corporis quod. Ea, dolor eius? Dolore, vel!
No annotations made yet
Congrats! You have your own personal workspace now.