Last updated on May 2018

Expanded Hemodialysis Versus Online Hemodiafiltration


Brief description of study

Conventional hemodialysis (HD) is essential for the treatment of end-stage renal disease (ESRD) patients, by reducing serum concentration of uremic toxins and correcting fluid overload.

Nevertheless, HD removes almost exclusively low-range uremic toxins. Therefore, medium-range molecules, such as beta-2-microglobulin might accumulate in tissues, leading to many clinical complications, such as neuropathies, tendinopathies, anemia, bone mineral disease and reduced growth in children.

Convective methods might reduce incidence of these complications, by removing molecules of medium-range molecular weight. Online hemodiafiltration (olHDF) is the most extensively used method in this regard. Nevertheless, there are some barriers to the wider introduction of this method in clinical practice, since specific machines are needed for this procedure, the costs with dialysis lines are higher and water consumption increases. More recently, the development of new membranes for hemodialysis allowed removal of medium- and high-range uremic toxins, with albumin retention. Thus, they allow removal of a broad range of uremic toxins, without changing dialysis machine or increasing water consumption. Such therapy is known as expanded hemodialysis (HDx).

The aim of this present study is to compare the extraction of middle-size molecules, the hemodynamic behavior, fluid and nutritional status of patients submitted to olHDF or HDx, in a crossover study.

Detailed Study Description

Hypothesis

Our hypothesis is that HDx is noninferior to olHDF in the following parameters:

  • Hemodynamic stability
  • Nutritional and fluid status
  • Removal of beta-2 microglobulin

Objectives To evaluate each patient, through a prospective, randomized and cross-over study, the intradialytic hemodynamic behavior, fluid and nutritional status assessed by electrical bioimpedance and B2M removal in two dialytic modalities: HDFol versus HDx.

Concise methods

  1. Clinical and laboratorial data Clinical data will be collected from the institution's chart, recorded and filled with all necessary precautions to keep confidentiality of patient's information. They are: baseline renal disease, age, history of smoking, sedentary lifestyle, presence of comorbidities such as hypertension and diabetes mellitus, family history of cardiovascular disease, history of coronary and cerebrovascular disease and medications.

Laboratory tests used to determine the biochemical, hematological and bone mineral profile characteristics will be obtained from routinely collected exams. Such exams are processed by the Central Laboratory of Hospital das Clnicas / FMUSP.

2. Dialysis All dialysis procedures will be performed by the Dialog+ Admea machine (BBraun Melsungen AG, Germany).

The olHDF will be prescribed as follows: blood flow 350 - 400 ml/min, dialysate flow 800 ml/min, post-dilution flow (90-100 ml/min), with high-flux Xevonta (BBraun Melsungen AG, Germany) or CAHP/DICE (Baxter Healthcare Corporation, Germany) dialyzers, with surface area of 1.7-2.4 m. The duration of each session will be from 3,5h to 4h, depending on current dialysis prescription. Total substitution volume will be higher than 20 L per session.

HDx will follow the same prescription of olHDF, regarding blood and dialysate flows and dialysis duration. There will be no substitution volume. Theranova dialyzers (Baxter Healthcare Corporation, Germany) will be used for each session.

Before initiating protocol and during the washout period, patients will be submitted to high-flux HD, which is the standard treatment in our service.

3. Hemodynamic monitoring Cardiac output index (CI), stroke volume (SV - integrated mean of the flow waveform between the current upstroke and the dichotic notch), peripheral arterial resistance (PAR - ratio of mean arterial pressure to stroke volume multiplied by heart rate) and blood pressure (BP) will be accessed by finger beat to-beat monitor Finometer (Finapress Medical Systems BV, Arnhem, The Netherlands), within 15 minutes after starting olHDF or HDx sessions (predialysis) and again, 15 minutes before its end (post-dialysis).

4. Bioelectrical impedance Segmental tetrapolar bioelectrical impedance (BIS) will be performed in all patients while recumbent, before starting study protocol and before each phase of the study (HDx or olHDF), by the multifrequency InBody S10 (Biospace Co., Ltd., Korea) device. It allows assessment of the following parameters regarding body fluids: total body water, total extracellular body water, lower limbs total water content, lower limbs extracellular water content. Additionally, -angle, which is a marker of cellular integrity and nutritional status, will be noted.

5. Blood and Effluent samples Blood samples will be collected pre-session, mid-session and post-dialysis sessions, both in the first and last dialysis sessions of each of the periods studied (HDFol or HDx). Pre-session blood samples will be collected immediately after arteriovenous fistula puncture and the middle and post-session samples will be collected from the arterial line, 2 minutes after reduction of blood flow to 50 ml/min and suspension of dialysate flow and/ or replacement.

In addition, partial and homogeneous collection of the effluent will be performed by a drainage hose, with an infusion pump operating continuously at a rate of 1l/h. The whole effluent of dialysis session will be collected.

Clinical Study Identifier: NCT03274518

Contact Investigators or Research Sites near you

Start Over

Recruitment Status: Open


Brief Description Eligibility Contact Research Team


Receive Emails About New Clinical Trials!

Sign up for our FREE service to receive email notifications when clinical trials are posted in the medical category of interest to you.